                          How many Smart-Ex Intrinsically Safe barcode scanner wireless can be connected to one PC in 1 time.
                      14/Dec/2017Here´s the result:
 Firmware Version 1.1.0.1 (Ident-Ex as Slave)
 Maximum active HID connections: 9
 Maximum active SPP connections: 7
 
 Firmware Version 1.6.10.0 (Ident-Ex as Master)
 Maximum active HID connections: 5
 Maximum active SPP connections: 2
 
 If the maximum numbers of active connections was reached and a new connection will be established, two thinks could happen:
 The connection could not be establishedThe connection will be established and another active connection will be lost
 Reading and writing data to all connected devices is possible, also if 9 devices were connected with HID Profile.
 
 If “HID Autoconnect” was enabled and more Ident-Ex’s than the maximum number of active connections were in range, the devices who can establish a connection accords to the random principle.
 
 The maximum numbers of active connections is limited by the Bluetooth module of the PC (normally up to 7 active connections).
 Tested with Broadcom 2070 Bluetooth Module.
 
 |