"For the above-tested models, Datalogic scanners are snappy as well as Honeywell. Especially for the OCR scanning.
However, configuration-wise, Honeywell is easier to configure. The more advanced functions are not accessible at our end and require Datalogic to assist.
For Honeywell scanners:
Original FW of scanners: Currently, it is an Either-Or situation when comes to OCR scanning of Passport or Cheque. The settings cannot be set concurrently. When OCR Passport is enabled, the OCR cheque will not work and vice-versa.
After applying trial FW (ver: EV000331DAC) from Honeywell-Shawn: Both 1950GSR and1950GHD can do OCR Passport and Cheque MICR within 1 setting. (Can OCR Passport or cheque upside down too)
For Datalogic scanners:
There is only 1 option for cheque scanning which is the Italian ITB Bank OCR and it doesn't work for scanning our (OCBC) cheque.
Conclusion:
- Datalogic models are more snappy but configuration cannot perform OCR passport and cheque within the same setting.
- Honeywell models can do both OCR passport and cheque within the same setting and have an easier-to-use configuration interface.
- If OCR Passport and OCR Cheque MICR are required at the same setting, then the Honeywell 1950GHD-2USB-A and Honeywell 1950GSR-2USB-A are the better all-rounded scanners.
- All rounded winner: Honeywell 1950GHD-2USB-A and Honeywell 1950GSR-2USB-A
GD4590-BK-HD: obj Sense: (on stand w/o magnet) (aimer on) (auto scan)
obj Sense: (on stand with magnet) (aimer on) (auto scan) (same result with or without magnet)
Single Trigger: (on stand w/o magnet) (aimer off) (manual trigger)
Single Trigger: (on stand with magnet) (aimer on) (once sense object in front of the scanner, illuminate & auto scan)
GD4520-BKK1S:
obj Sense: (on stand w/o magnet) (aimer on) (manual trigger)
obj Sense: (on stand with magnet) (aimer on) (auto scan) (same result with or without magnet)
Single Trigger: (on stand w/o magnet) (aimer off) (manual trigger)
Single Trigger: (on stand with magnet) (aimer on) (once sense object in front of the scanner, illuminate & auto scan)
Datalogic GBT4500-BK-HD-WLC:
objSense: (in cradle) (aimer on) (auto scan)
objSense: (BT to computer, no cradle) (aimer on) (auto scan)
Single Trigger: (in the cradle) (aimer off) (manual trigger)
Single Trigger: (BT to computer, no cradle) (aimer off) (manual trigger)
* BT: Bluetooth
* obj Sense: Using configurations from GD45 OCR Passport ObjSense 19 Jun 20.pdf
* Single Trigger: Using configurations from GD45 OCR Passport SingleTrigger 19 Jun 20.pdf